Experience with Biodegradable Polymer Coated Sirolimus-Eluting Coronary Stent System in “Real-Life” Percutaneous Coronary Intervention: 24-Month Data from the Manipal-S Registry

Shetty, Ranjan and Thakkar, Ashok and Mishra, Supriya Sunder and Joseph, Vivek and Tumkur, Anil and Pai, Umesh (2013) Experience with Biodegradable Polymer Coated Sirolimus-Eluting Coronary Stent System in “Real-Life” Percutaneous Coronary Intervention: 24-Month Data from the Manipal-S Registry. Journal of Clinical and Diagnostic Research., 7 (9). pp. 1959-1963.

[img] PDF
35- 5915_E(C)_F(T)_PF1(PF1(PRP)_PFA(NC).pdf - Published Version
Restricted to Registered users only

Download (387kB) | Request a copy

Abstract

Introduction: Despite the undeniable clinical efficacy of drug-eluting stents with durable polymers, concerns regarding their long-term safety have been raised, especially in more complex subsets. The Manipal-S Registry was designed to evaluate the safety and effectiveness of the biodegradable polymer coated Supralimus® Sirolimus-Eluting Coronary Stent for the treatment of coronary artery disease, across a wide range of patients who are treated in real-life clinical practice. Methods: All the consecutive 116 patients who underwent single-vessel or multiple vessel percutaneous coronary interventions with the use of Supralimus® sirolimus-eluting stents between September 2009 and December 2010, were included in this study. Patients were clinically followed-up at 1, 9, 12 and 24 months post-procedure. All clinical, procedural, and follow-up information were collected and analysed. Results: In total 116 patients, 126 lesions were implanted with 144 stents which had an average stent length of 25.8±8.0 mm. The incidences of any major adverse cardiac and cerebral events at 1, 9, 12 and 24 months were 0, 5 (4.3%), 8 (6.9%), and 10 (8.6%) respectively. Conclusion: These 24-month results clearly provide evidence for safety and effectiveness of the Supralimus® Sirolimus-eluting coronary stent system with the biodegradable polymer in real-life patients, even in those with acute myocardial infarctions.

Item Type: Article
Uncontrolled Keywords: Coronary artery disease; Biodegradable polymer; Sirolimus-eluting stent
Subjects: Allied Health > MCOAHS Manipal > Cardiology
Medicine > KMC Manipal > Cardiology
Pharmacy > MCOPS Manipal > Pharmacy Practice
Depositing User: KMC Manipal
Date Deposited: 10 Jun 2014 11:10
Last Modified: 10 Jun 2014 11:10
URI: http://eprints.manipal.edu/id/eprint/139693

Actions (login required)

View Item View Item