Comparison of radiation dose in brain imaging between 64 slice and 16 slice Ct

Islam, Jawad T and Yadav, Sushil and Kotian, Rahul P (2015) Comparison of radiation dose in brain imaging between 64 slice and 16 slice Ct. International Journal of Scientific Research, 4 (6). pp. 394-395. ISSN 2277 - 8179

[img] PDF
Comparison of Radiation Dose in Brain 2015.pdf - Published Version
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

Aim:Comparison of radiation dose in brain imaging between 16 and 64 slice CT. Materials and Methods:Sampling was done by convenience sampling method considering inclusion and exclusion criteria and a sample of 80 was included. 40 were scanned in 64 slice CT and 40 were scanned in 16 slice CT. Effective dose was computedfrom DLP using the equation; Eek: x DLPk=0.0021 (According to European guidelines). Statisticalanalysis was done using Mann-Whitney U test.Result:The 16 slice CT machine is delivering more radiation dose compared to 64 slice CTfor brain imaging with statistically significant difference. Conclusion.In the context of brain CT imaging using the same softwarefrom the same manufacturer, 64CT examinations provide gives a lower ED when compared with 16CT examinations.

Item Type: Article
Uncontrolled Keywords: Computer tomography; effective dose; stochastic effect; CTDlvol; and DLP.
Subjects: Allied Health > MCOAHS Manipal > Medical Imaging Tech
Depositing User: KMC Manipal
Date Deposited: 21 Jul 2015 04:21
Last Modified: 21 Jul 2015 04:21
URI: http://eprints.manipal.edu/id/eprint/143403

Actions (login required)

View Item View Item