MU Digital Repository
Logo

A Comparison of Functional Outcomes After Metallic and Bioabsorbable Interference Screw Fixations in Arthroscopic ACL Reconstructions

Hegde, Atmananda S. and Rai, Deepak K and Kannampilly, Antony J (2014) A Comparison of Functional Outcomes After Metallic and Bioabsorbable Interference Screw Fixations in Arthroscopic ACL Reconstructions. Journal of Clinical and Diagnostic Research, 8 (4). LC01-LC03. ISSN 0973-709X

[img] PDF
jcdr-8-LC01 (1).pdf - Published Version
Restricted to Registered users only

Download (266kB) | Request a copy

Abstract

Introduction: Anterior Cruciate Ligament (ACL) is as one of the most frequently injured ligaments in the modern contact sports scenario. Graft fixations can be achieved during anterior cruciate ligament (ACL) reconstructions by using either bioabsorbable screws or metal screws. The objective of this study was to compare the functional outcomes after bioabsorbable and metallic interference screw fixations in arthroscopic anterior cruciate ligament reconstructions done by using hamstring grafts. Materials and Methods: This was a prospective, randomized study. Patients in Group 1 received bioabsorbable interference screws and patients in Group 2 received metallic interference screws. Arthroscopic assisted, anterior cruciate ligament reconstructions with the use of hamstring grafts which were fixed proximally with endobuttons and distally with bioabsorbable or metallic interference screws, were undertaken. Progress in functional outcomes was assessed by using Mann Whitney U- test. Functional outcomes in the two groups were compared by using independent t-test. Observation and Results: In each group, there were statistically significant improvements in functional outcomes over successive follow-ups, which were seen on basis on Mann-Whitney U-test. The comparison of functional outcomes between the two groups, done by using independent t-test, showed no statistically significant differences between the two groups at 3 months, 6 months and 1 year of follow-up. p-value <0.05 was considered to be significant in our study. Conclusion: In our prospective study of comparison of functional outcomes between bioabsorbable and metallic interference screws in arthroscopic anterior cruciate ligament reconstuctions, which were evaluated by using Tegner activity scale and Lysholm knee scoring scale for a period of 1 year, no statistically significant difference was found. However, further authentication is required by doing long term studies.

Item Type: Article
Uncontrolled Keywords: ACL reconstruction, Bioabsorbable and Metallic interference screws
Subjects: Medicine > KMC Mangalore > Orthopaedics
Depositing User: KMCMLR User
Date Deposited: 09 Feb 2016 15:11
Last Modified: 09 Feb 2016 15:11
URI: http://eprints.manipal.edu/id/eprint/145293

Actions (login required)

View Item View Item