Study of effect of lateral loads on different outrigger systems with belt truss

Sushma, S and Dhanalakshmi, . (2016) Study of effect of lateral loads on different outrigger systems with belt truss. International Journal of Research in Engineering and Technology (IJRET), 05 (04). pp. 378-382. ISSN 2277 – 4378

[img] PDF
1428.pdf - Published Version
Restricted to Registered users only

Download (374kB) | Request a copy
Official URL: http://www.esatjournals.org

Abstract

Outrigger systems are one of the efficient lateral load resisting structural forms used in design of tall buildings. The better performing system among All Steel, All concrete and Mixed Steel-Concrete outrigger systems, for a given site specific lateral loading is the main interest of study. Parameters like base shear, overturning moment and top displacement are compared in the multi outrigger system, with one outrigger fixed at the top and the position of the second varied. Mixed Steel and concrete system is found to be the efficient system. Second outrigger anywhere between 0.4 to 0.6 times the total heights of the building is found to be optimum

Item Type: Article
Uncontrolled Keywords: Multi Outrigger System, Belt Truss, Materials, ETABS
Subjects: Engineering > MIT Manipal > Civil Engineering
Depositing User: MIT Library
Date Deposited: 05 Nov 2016 11:10
Last Modified: 05 Nov 2016 11:10
URI: http://eprints.manipal.edu/id/eprint/147474

Actions (login required)